Online Double Conversion technology with stable and uninterrupted power and complete sine waveform in linear and non-linear load at maximum load consumption
Featuring an intelligent charger with suitable amperage for charging batteries of various capacities.
Equipped with an appropriate inverter for extended backup time.
Device dimensions: 440mm width, 468mm depth, 88mm height (440×468×88mm).
Net weight of the device: 10.1 kg.
Input power factor 0.99 and Active Power Factor Correction (APFC)
Output Power factor of 0.9
DSP (digital signal processors )control technology
Input voltage range from 110 volt to 300 volt
Wide input frequency range for operation with variety of generators in the range of 40 to 70 Hz and proper stabilization of the output frequency of 50 Hz with a telorance of 0.1
LCD display to show input and output voltage, power as VA & frequency, inside temperature of the device, battery charge and load consumption rate
Adjust the output Voltage,Selectable battery shutdown voltage (EOD) , automatic start, bypass mode and and ECO mode through the LCD display panel
Advanced Battery Management (ABM) to control battery charge , discharge and fast and stable charge in about three hours and prevention of excessive battery discharge
With EMI protection filters and RFI varistor and protection against over current and over voltage, short-circuit, DC reverse voltage and lightning
Start without the need for city electricity (Cold Start) and automatic start-up after connecting the city electricity and settable delayed start when power is restored
Flexible battery configuration in UPS 6K & 10K (168/180/192/204/216/228/240 settable)
Adjust the output frequency at 50 and 60 Hz and has Auto Sensing Frequency
Effective software and hardware protection
Function at relative Humidity between 0 to 95% and temperature between 0 to 40 degrees Celsius
Turn off the device automatically in on sump hot no-load mode (ECO Mode)
Shut down automatically in emergency time
Communication with PC by RS232 (standard), USB / RS485 / SNMP / Dry Call (optional)
<![if supportMisalignedColumns]>
<![endif]>
| MODEL |
|
HT 6010 |
HT 6020 |
HT 6030 |
HT 6060 |
HT 6100 |
| POWER |
VA |
i1000 |
i2000 |
i3000 |
i6000 |
i10000 |
| W |
i900 |
i1800 |
i2700 |
i5400 |
i9000 |
| INPUT |
Rated voltage |
i208 / 220 / 230 / 240 V |
| Voltage range |
i110 ~i176 V (linear derating between 50% and 100% load); 176 ~ 280 V (no derating) |
| Frequency |
i40 ~i70 Hz (auto-sensing) |
| Power factor |
≥i0.i99 full load |
| Total harmonic distortion |
THDI ≤i5% |
| Bypass voltage range |
i160 ~i255% (settable) |
i135 ~i255% (settable) |
| OUTPUT |
Voltage |
i208 V/ 220 V/ 230 V/ 240 V (settable via LCD) |
| Voltage regulation |
i1% |
| Frequency |
i50/i60 Hz i0.i1 Hz (battery mode) |
| Power factor |
i0.i9 |
| Waveform |
Sinusoidal |
| Crest factor |
i3:1i |
| Total harmonic distortion |
THDV≤i2%(linear load); < 5% (non-linear load) |
THDV≤i1%(linear load); <4%(non-linear load) |
| Overload |
i105% ~ 125% for 1 min_i125% ~i150% for 30 s |
| Transfer time |
i0 ms |
| BATTERIES |
Charging current |
internal model |
i1A |
| external model |
i6A |
i5A –i12A (optional) |
| DC voltage |
i36 |
i72 |
i72~i96 |
i192~i240 |
| SYSTEM |
ECO mode |
≥i95 % |
≥i96 % |
≥i97 % |
≥i98 % |
| Protections |
Short-circuit,overload, overtemperature, battery discharge protection and fan testing protection |
| communications |
RS232 (standard) , USB (optional) , SNMP (optional) |
| Max.paraller connections |
i4 |
| Display |
LCD |
| Alarms |
Utility failure – Low battery – Overload – UPS fault |
| OTEHRS |
Operating temperature |
i0°C ~i40°C |
| Relative humidity |
i0~i95% (non-condensing) |
| IP rating |
IP 20 |
| Noise level at 1m |
≤i50 dB |
≤i55 dB |
≤i58 dB |
| PHYSICAL |
Dimensions (WxDxH)(mm) |
internal (N) |
i440 x 468 x 88 |
i440 x 560 x 88 |
i440 x 560 x 88 |
i440 x 660 x 176 (UPS) |
| external (X) |
i440 x 430 x 88 |
i440 x 468 x 88 |
i440 x 468 x 88 |
i440 x 580 x 88 (Battery Case) |
| Packaged dimensions (WxDxH)(mm) |
internal (N) |
i545 x 560 x 201 |
i545 x 690 x 201 |
i545 x 960 x 201 |
i514 x 696 x 161(UPS) |
| external (X) |
i545 x 592 x 201 |
i545 x 592 x 201 |
i545 x 592 x 201 |
i554 x 792 x 418 (Battery Case) |
| Net weight (kg) |
i15.8 (N) |
i7.6 (X) |
i26 (N) |
i9.7 (X) |
i26.8 (N) |
i10.1 (X) |
i58 (N) |
i12 (X) |
i63 (N) |
i14 (X) |
| Gross weight (kg) |
i18.9 (N) |
i11.1 (X) |
i25.8 (N) |
i13.2 (X) |
i29.4 (N) |
i13.6(X) |
i68 (N) |
i14 (X) |
i73 (N) |
i16 (X) |